Calibration Data
Appendix status: Initial index
Raw observations are preserved in the repository. Chapter prose must cite the input file and distinguish raw measurements from derived parameters.
Encoder and motion calibration
Artifact |
Purpose |
Current conclusion |
|---|---|---|
Ground-truth motion trials |
Supports the \(\sqrt{2}\) translation correction; full uncertainty campaign pending |
|
Applied calibration constants |
CPR 2779, all signs |
Ultrasonic calibration
Artifact |
Purpose |
Current conclusion |
|---|---|---|
Raw two-sensor samples |
2 sensors x 4 distances x 100 samples |
|
Group statistics |
Supports \(\sigma(d)=0.0017+0.0078d\) m |
|
Map/sensor end-to-end test |
True pose outscored shifted poses in all four positions |
Reproducibility rule
A parameter belongs in a completed chapter only when its acquisition method, units, sample count, raw input, transformation, and verification result are all available. Theoretical defaults must remain labeled as theoretical.